Bonjour,
Un client nous appelle au secours suite à la désactivation de son serveur par
Online.
En guise d'explication, nous avons (je cite) :
Dec 19 10:15:26: %SW_DAI-4-PACKET_RATE_EXCEEDED: 51 packets received in 838
milliseconds on Gi1/0/27.
Dec 19 10:15:26: %PM-4-ERR_DISABLE: arp-inspection error detected on Gi1/0/27,
putting Gi1/0/27 in err-disable state
Dec 19 10:15:27: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet1/0/27, changed state to down
Dec 19 10:15:28: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/27, changed state
to down
Dec 19 10:20:26: %PM-4-ERR_RECOVER: Attempting to recover from arp-inspection
err-disable state on Gi1/0/27
Dec 19 10:20:32: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/27, changed state
to up
Dec 19 10:20:33: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet1/0/27, changed state to up
Si je lis ça rapidement, ca explique que le port a été passé en shutdown parce
que le serveur aurait émis 51 packets en 0.838 secondes. Euuuuuh, c'est un
comportement anormal ça ?
'fin bref, je veux bien croire qu'il y ai un soucis de conf réseau sur la
machine mais les explications de la part d'Online sont (pour tester poli)
laconiques non ? Ou alors ils considèrent que tous leurs clients sont CCNA. Moi
qui n'ai jamais voulu entendre parler de cisco sur mon backbone, ca me fait une
belle jambe.
Ca vous parle un truc comme ça ?
Merci,
Julien